1. Turn off the switch and fuse the operating circuit. It can be a single-phase grounding connected to the protection mechanism in the crane operation circuit. Check insulation and eliminate grounding.
2. The line contactor K0 (LX electric single beam suspension crane) of the crane cannot be connected. There are several reasons for this failure:
3. After the line contactor is closed, introduce the fuse on the line, check whether the phase is grounded, find out the grounding point with an insulation resistance meter and eliminate it.
4. When the line contactor is closed, the overcurrent relay acts and the contactor releases automatically. Check whether the circuit of the controller is grounded, disconnect the wire on the protection panel from the controller, and then connect it step by step. The contactor shall be connected once every time the conductor is connected. Determine the grounding controller according to the action of overcurrent relay, and then calculate the grounding point through insulation resistance meter.
5. When the controller is closed, the overcurrent relay acts. The causes of this fault are as follows: