Common fault causes and treatment methods of seamless sliding contact line

Because the seamless sliding contact line is easy to use and install, and the overall appearance is beautiful, it has become a widely used power supply method for indoor bridge cranes. But the sliding contact line has been used for a long time, and some problems will inevitably occur. The editor of our factory will introduce to you the causes and solutions of common failures of seamless sliding contact lines.

Seamless sliding contact line
1. The guide rail is deformed and the operation of the collector is blocked

The main reason: the ambient temperature is too high; the distance between the lifting racks is large or loose.

Treatment method: Partially use heat insulation board and add sun visor outside; increase the number of sliding contact wire lifting racks, correct the conductor and tighten the screws.

2. There is a big abnormal noise when the sliding contact line collector is walking

Main reasons: excessive current; uneven joints.

Solution: increase the number of current collectors; readjust the rail connection.

3. There is a spark in the conductor

The main reason: poor contact between the brush surface and the guide rail.

Treatment method: check the conductor joints, properly break in the brushes, and ensure 60% of the contact area.

4. Scratches on the side of the brush

The main reasons: the brush is worn, the current collector is not positioned correctly; the force transmission of the puller side of the tractor is too large.

Treatment method: replace and modify the spring pressure; replace the traction fork or modify the retractor fork.

5. The sliding contact line shakes a lot when working

The main reasons: the fork can not absorb the transmission error; the straightness of the guide rail is poor; the lifting rack is loose.

Treatment method: correct the tractor so that it can freely absorb the transmission error; adjust the straightness of the guide rail; tighten the screw of the lifting bracket.

6. Scratch on the shell of the sliding contact line collector

Main reasons: deformation of the conductor; poor positioning of the current collector.

Solution: According to the second fault, add the lifting rack; adjust the collector.

7. The brush wears out quickly

Main reasons: uneven joints; excessive current carrying capacity; high spring pressure.

Treatment method: reconnect the guide rail as required; increase the number of collectors; replace and modify the spring pressure.

8. Power off the sliding contact line

The main reasons: the brush is climbing in the conductor; the brush is severely worn and the conductor cannot be touched; the conductor joint is not flat; the single current collector is used; the rail joint is loose.

Treatment method: check whether the current collector brush is severely worn, replace the current collector brush; replace the brush to re-adjust the connection node; use a double-brush current collector; re-adjust and tighten the connection screw.

The seamless sliding contact line is a wear part. The user should check the use of the part frequently. If the wear is serious, it should be replaced in time. You can contact our factory.